CZone AC Output Interface (ACOI)
Simplify the way you network, monitor and control onboard AC circuits. The AC Output Interface does it all and provides circuit protection for all onboard AC devices. It is easy to install, configure and operate the digital control system with pre-wired components for quick connections. This gives you a customizable solution to suit unique installation and application needs, including ‘night running’ or ‘at anchor’ as well as control at multiple locations. It has eight outputs (up to 50A each), supports multiple pole designs and multiple separate buss feeds. To make it easy, status
ACOI Standard Sample
The ACOI us usually made to order based on system design and requirements. A Typical module would consist of the following:
- 8 x 50A relays protected with 10A MCB’s
- Pre-wired
- Current monitoring on each channel
- IPX5 enclosure
- Dimensions (HxWxD): 17" x 10.8" x 7.3" / 430 x 276 x 186 mm
- Contact us with your requirment for a custom quote
ACOI Dinrail Mount
Available as an alternative where a custom AC Breaker Panel will be made. Available for either USA (ABYC) standard Black Wire Tails or APAC/Europe Brown Wire Tails.
- 8 x 50A relays
- Fitted with 600 mm tails
- Cost effective solution, own enclosures and MCB's can be sourced
- Current monitoring on each channel
- Dimensions (HxWxD): 3" x 6.3" x 2.4” / 77x160x60 mm
- Custom Cabinet and Circuit Breakers required under most clasification societies.
Specifications:
- Circuit status and run current displayed for each circuit
- Customizable to suit installation requirements
- Pre-wired for quick connection
- Staggered start up of loads
- 110V, 240V, 110/220V
- Supports multiple pole designs, i.e. double, triple, four pole
- Utilizes standard DIN rail mounted components for circuit protection and control
- Can support two separate buss feeds (i.e. 2 load groups) in one box
- Delay before circuits come on to allow generators to come up to speed
- Provides circuit protection and control
- Status LEDs at enclosure
- Manual bypass at enclosure
- Provision for MCB/RCDs
- Timers
- 50 or 60 Hz