CZone AC Mains Interface (ACMI)
A sophisticated source selector or transfer switch, the AC Mains Interface enables the user to specify which AC power source is actively supplying power to the ship (generator, inverter, or shore power). Developed for use with the CZone digital control system, but may also be used a stand-alone device.
SKU: ITA000389
หมายเลขชิ้นส่วนผู้ผลิต: 80-911-0068-00
The ACMI can be programmed to automatically change the supply source when the current rating is exceeded, and includes a manual override and user-friendly display screen that ensures easy current, voltage, frequency, and power monitoring. Other features include six monitored, over-current protected main power inputs of up to 100A each, as well as two outputs, which enables two separate load groups and a parallel option for use with a single source. To simplify installation, the ACMI comes pre-wired for easy installation.
ACMI Standard Sample Configuration
- Three (3) Inputs—1x 16A Shore Power, 1x 32A
- Shore Power, 1x 50A Generator with Parallel
- Two (2) Load Groups—40A
- 230V AC 50Hz
- Current, voltage, frequency and power monitoring incorporated
- Manual override panel on enclosure
- Dimensions (HxWxD): 17" x 21.3" x 7.3" / 430 x 540 x 186 mm
ACMI is a custom ordered product. Each Customer's ACMI will vary based on their requirements. Contact your account manager for requirements.
Specifications:
- 6 Source inputs up to 125A (eg. 2x shore power, 2x generator)
- Monitoring of channel status (on/off/fault)
- Provides circuit protection and control
- Manual override at enclosure and via remote panel
- Customizable to suit installation requirements
- Supports multiple pole designs, i.e. double, triple, four pole
- 110V, 240V, 110/220V
- IPX5 enclosure
- Utilizes standard DIN rail mounted components for circuit protection and control
- Current, voltage, frequency and power monitoring incorporated (six channels)
- Physical and software lockouts between source controls (prevents two sources from becoming connected)
- Reverse polarity and bad power supply alarms including auto disconnect and lockouts
- 2 Outputs (load groups), allows for two separate load groups with parallel option for use with single source
- Auto changeover (non-seamless)
- Provision for RCD’s
- Load shedding
- Status LEDs at enclosure
- Pre-wired for quick connection
- Timer controls
- 50 or 60 Hz