ค้นหา
Filters
Close
Hella Marine SeaHawk XL Dual Colour Floodlights

Get the best of both worlds. Use Hella Marine's SeaHawk XL Dual Colour Floodlights to give two colour options in one.

EMU-1-BAS Analogue Engine to NMEA2000 converter

The Actisense EMU-1 is a specialized analogue to NMEA 2000 Gateway which converts data from analogue engine gauges/senders into NMEA 2000 data. The EMU-1 enables the sharing of engine data throughout the NMEA 2000 bus. It digitises analogue engine sensors, enabling NMEA 2000 display devices to monitor the connected engine(s) on a vessel. The EMU-1 can monitor vital engine parameters such as temperature, pressure RPM and fluid levels from up to two engines.
SKU: ITA040795
หมายเลขชิ้นส่วนผู้ผลิต: EMU-1-BAS
ผู้ผลิต: Actisense
฿22,510.00 รวมภาษี

EMU-1 Engine Monitoring Unit

The EMU-1 has a PC based configuration tool that allows the settings inside the EMU-1 to be changed to best suit the engine it is working with, making it a flexible solution for many engine makes and models. An Actisense PC to NMEA 2000 Gateway (NGT-1) is required to configure the EMU-1.

It is recommended that an NGT-1 is available for every EMU-1 installation. The NGT-1 can be used to update the firmware, connect the Toolkit and display data on a PC for diagnostic and information purposes, using NMEA Reader. Please visit the NGT-1 page for product details.

FEATURES

  • Enables analogue signals to be converted to NMEA 2000 messages
  • Convert signals from up to two engines (that share a common ground) with a single EMU-1
  • 6 gauge / parameter inputs
  • 4 alarm inputs
  • 2 additional auxiliary inputs
  • 2 Tacho inputs
  • Customised IP65 case
  • Diagnostic LED’s
  • Wide power compatibility of 9 to 35 Vdc

BENEFITS

  • No need to change an existing engine
  • Easy installation
  • Easy to configure to suit the connected engine
  • Connect signals from fluid level gauges (that share a common ground with the engine) to NMEA 2000®
  • Optional DIN rail mounting kit available
  • Total engine hours are logged by the monitoring of engine Tach (RPM) input

Specifications

Power Supply

Supply Voltage9 to 35V DC
Supply CurrentTypically < 25mA @ 12V DC
Supply ProtectionContinuous reverse polarity protection and load dump protection (meets SAE J1113)
Supply ConnectorPluggable 2-way screw terminal, 3.5mm pitch
Supply Voltage (NMEA 2000 Port)9 to 29V DC
Supply Current (NMEA 2000 Port)< 20mA @ 12V DC from NMEA 2000 bus
Load Equivalent Number (LEN)1
Supply Protection (NMEA 2000 Port)Continuous reverse polarity protection and overvoltage protection to 40V

NMEA2000 Port In/Out

CompatibilityFully NMEA 2000 certified
Galvanic Isolation2500V input to ground, 1500V output to ground using ISO-Drive
Speed / Baud Rate250kbps
NMEA 2000 ConnectorM12 male (A coded) connector

Gauge Inputs

Voltage Range0 to 35V DC
Input Impedance> 50kΩ
Sender Feed0, 4 or 18mA
Accuracy<= 2%
Input ConnectorPluggable 6-way screw terminal, 3.5mm pitch
Input ProtectionOvervoltage protection to ±40V

Alarm Inputs

Voltage Range0 to 37V DC
Input Impedance> 50kΩ
Threshold VoltageConfigurable, default is 5V
Alarm PolarityConfigurable, default is alarm on low input
Accuracy<= 2%
Input ConnectorPluggable 4-way screw terminal, 3.5mm pitch
Input ProtectionOvervoltage protection to ±40V

Tacho Inputs

Voltage Range±3 to ±60V
Input Impedance> 100kΩ to ground
Input Pulse Range4 to 50,000Hz
Accuracy<= 1%
Sender CompatibilityIgnition coil, alternator (“W”, “R” or “AC”) terminal, hall effect, VR or inductive sender
ThresholdAutomatically adjusts to signal level
Input ConnectorPluggable 4-way screw terminal, 3.5mm pitch
Input ProtectionCan withstand an ignition pulse to ±500V

Engine Log

Engine Hours2 separate engine hour logs internally connected to the tacho Inputs. Hours are logged when RPM is present, stored in non-volatile memory

Mechanical

Housing MaterialPolycarbonate
Protective Lid MaterialPolycarbonate
Sealing MaterialsExpanded silicone foam gasket, closed cell polyurethane splash guard and ePTFE waterproof vent
Dimensions127mm (L) x 112mm (W) x 48mm (H)
Weight250g
Mounting4 x 3.5mm lugs to allow panel mount with self tapping s/s screws (included), optional DIN Rail mount available on request

Approvals & Certifications

Fully NMEA 2000 Certified
EMCEN 60945 (sections 9 & 10)
Environmental ProtectionIP66 (PCB housing)
Operating Temperature-20°C to +55°C
Storage Temperature-30°C to +70°C
Recommended Humidity0 – 93% RH
Guarantee3 years

For more details and Downloads please visit Actisense Website at:

https://www.actisense.com/products/emu-1-nmea-2000-engine-data/

EMU-1 Engine Monitoring Unit

The EMU-1 has a PC based configuration tool that allows the settings inside the EMU-1 to be changed to best suit the engine it is working with, making it a flexible solution for many engine makes and models. An Actisense PC to NMEA 2000 Gateway (NGT-1) is required to configure the EMU-1.

It is recommended that an NGT-1 is available for every EMU-1 installation. The NGT-1 can be used to update the firmware, connect the Toolkit and display data on a PC for diagnostic and information purposes, using NMEA Reader. Please visit the NGT-1 page for product details.

FEATURES

  • Enables analogue signals to be converted to NMEA 2000 messages
  • Convert signals from up to two engines (that share a common ground) with a single EMU-1
  • 6 gauge / parameter inputs
  • 4 alarm inputs
  • 2 additional auxiliary inputs
  • 2 Tacho inputs
  • Customised IP65 case
  • Diagnostic LED’s
  • Wide power compatibility of 9 to 35 Vdc

BENEFITS

  • No need to change an existing engine
  • Easy installation
  • Easy to configure to suit the connected engine
  • Connect signals from fluid level gauges (that share a common ground with the engine) to NMEA 2000®
  • Optional DIN rail mounting kit available
  • Total engine hours are logged by the monitoring of engine Tach (RPM) input

Specifications

Power Supply

Supply Voltage9 to 35V DC
Supply CurrentTypically < 25mA @ 12V DC
Supply ProtectionContinuous reverse polarity protection and load dump protection (meets SAE J1113)
Supply ConnectorPluggable 2-way screw terminal, 3.5mm pitch
Supply Voltage (NMEA 2000 Port)9 to 29V DC
Supply Current (NMEA 2000 Port)< 20mA @ 12V DC from NMEA 2000 bus
Load Equivalent Number (LEN)1
Supply Protection (NMEA 2000 Port)Continuous reverse polarity protection and overvoltage protection to 40V

NMEA2000 Port In/Out

CompatibilityFully NMEA 2000 certified
Galvanic Isolation2500V input to ground, 1500V output to ground using ISO-Drive
Speed / Baud Rate250kbps
NMEA 2000 ConnectorM12 male (A coded) connector

Gauge Inputs

Voltage Range0 to 35V DC
Input Impedance> 50kΩ
Sender Feed0, 4 or 18mA
Accuracy<= 2%
Input ConnectorPluggable 6-way screw terminal, 3.5mm pitch
Input ProtectionOvervoltage protection to ±40V

Alarm Inputs

Voltage Range0 to 37V DC
Input Impedance> 50kΩ
Threshold VoltageConfigurable, default is 5V
Alarm PolarityConfigurable, default is alarm on low input
Accuracy<= 2%
Input ConnectorPluggable 4-way screw terminal, 3.5mm pitch
Input ProtectionOvervoltage protection to ±40V

Tacho Inputs

Voltage Range±3 to ±60V
Input Impedance> 100kΩ to ground
Input Pulse Range4 to 50,000Hz
Accuracy<= 1%
Sender CompatibilityIgnition coil, alternator (“W”, “R” or “AC”) terminal, hall effect, VR or inductive sender
ThresholdAutomatically adjusts to signal level
Input ConnectorPluggable 4-way screw terminal, 3.5mm pitch
Input ProtectionCan withstand an ignition pulse to ±500V

Engine Log

Engine Hours2 separate engine hour logs internally connected to the tacho Inputs. Hours are logged when RPM is present, stored in non-volatile memory

Mechanical

Housing MaterialPolycarbonate
Protective Lid MaterialPolycarbonate
Sealing MaterialsExpanded silicone foam gasket, closed cell polyurethane splash guard and ePTFE waterproof vent
Dimensions127mm (L) x 112mm (W) x 48mm (H)
Weight250g
Mounting4 x 3.5mm lugs to allow panel mount with self tapping s/s screws (included), optional DIN Rail mount available on request

Approvals & Certifications

Fully NMEA 2000 Certified
EMCEN 60945 (sections 9 & 10)
Environmental ProtectionIP66 (PCB housing)
Operating Temperature-20°C to +55°C
Storage Temperature-30°C to +70°C
Recommended Humidity0 – 93% RH
Guarantee3 years

For more details and Downloads please visit Actisense Website at:

https://www.actisense.com/products/emu-1-nmea-2000-engine-data/